FEC Micro Nutrunner Operations Manual Chapter 3: System Description (Rev 2: 02/12)
Page 3-5
START
REV.
CAL RESET
DATA
PARM.
D-NO.
MODE
SET
RS232C
SAN3-DP2
DATA
3.3 MNR Keyboard-Display unit description
The display unit incorporates programming and monitor functions display into the MNR controller.
It comes standard within the MNR unit. Programming of parameters can be accomplished using
the programming keys as well as displaying the fastening result data from the LED display. The
included RS232 9 pin connector allows User Console communication or the output of fastening
data to host or monitor systems.
NOTE: Refer to Chapter 7 for detailed operation using the keyboard/display unit.
3.3.1 RS232C Serial Pin out
Connector: DB-9P (Male)
Mating Connector: DB-9S (Female)
PIN SIGNAL DESCRIPTION
1 NOT USED
2 RXD NOT USED
3 TXD TRANSMIT DATA
4 DTR DATA TERMINAL READY (ALWAYS ON)
5 GND SIGNAL GROUND
6 DSR NOT USED
7 RTS REQUEST TO SEND (ALWAYS ON)
8 CTS CLEAR TO SEND
9 NOT USED
Note: The CTS signal needs to be activated in order for the fastening data to be output. If it is
not activated, up to 16KB of data will be stored in the output buffer. Once the buffer is full, the
data will be overwritten in a First In, First Out (FIFO) process. The CTS signal may be con-