FEC FUSION Operations Manual Chapter 4: System Setup and Wiring (Rev. 2.1)
Page 4-47
I/O Signal Map
(Continued)
From PLC to Fusion – (4 Bytes – 32 Bits)
Octal
Bit
Description
Comment
O:00
0 0
1 1
2 2
3 3
4 4
5 5
6 6 Abort Job Reserved for Future Use
7 7 Reset
O:00
10 8
11 9
12 10
13 11
14 12 Work Select/Job 0 Job Function is Future
15 13 Work Select/Job 1 Job Function is Future
16 14 Work Select/Job 2 Job Function is Future
17 15 Work Select/Job 3 Job Function is Future
O:01
0 0 Stop
1 1 Reset
2 2 Reverse
3 3 Start
4 4 Bypass
5 5 Disable Self-check
6 6
7 7
O:01
10 8
11 9
12 10
13 11
14 12 In 12 Terminal Input 12 not assigned
15 13 In 13 Terminal Input 13 not assigned
16 14 In 14 Terminal Input 14 not assigned
17 15 In 15 Terminal Input 15 not assigned
Firmware Set-up
Two items are configurable in the set-up of the Fusion controller for the Allen Bradley Remote
I/O interface. Both the I/O Rack Starting Quarter and the Last Rack setting is set-up in the
system parameter settings.
I/O Starting Quarter
Sets the Starting Quarter for the rack address
WORK [00] Data No. [28]
“0”: 1
st
Quarter
“1”: 2
nd
Quarter
“2”: 3
rd
Quarter
“3”: 4
th
Quarter
Last Rack
Sets the Fusion system as the last rack or not on the Remote I/O link
WORK [00] Data No. [29]
“0”: Not Last Rack
“1”: Last Rack