Manual
FEC FUSION Operations Manual Chapter 4: System Setup and Wiring (Rev. 2.1)
Page 4-43
Profibus Signal I/O Map
(Continued)
Word
Byte
Bit
No.
Signal Description
Comment
4
8
0 65 Angle Integer bit 0
Outputs Fastening Angle value using
binary integer
0 - 9999 max.
Example:
bit 1, 2, 5, 7 Logical "1" = 166
1 66 Angle Integer bit 1
2 67 Angle Integer bit 2
3 68 Angle Integer bit 3
4 69 Angle Integer bit 4
5 70 Angle Integer bit 5
6 71 Angle Integer bit 6
7 72 Angle Integer bit 7
9
0 73 Angle Integer bit 8
1 74 Angle Integer bit 9
2 75 Angle Integer bit 10
3 76 Angle Integer bit 11
4 77 Angle Integer bit 12
5 78 Angle Integer bit 13
6 79
7 80
5-7
Byte
10-15
81
Not Used
128
From PLC to Fusion: 2 Words (4 Bytes – 32bits)
Word
Byte
Bit
No.
Description
Comment
0
0
0 1
1 2
2 3
3 4
4 5
5 6
6 7 Abort Job Reserved for Future Use
7 8 Reset
1
0 9
1 10
2 11
3 12
4 13 Work Select/Job 0 Job Function is Future
5 14 Work Select/Job 1 Job Function is Future
6 15 Work Select/Job 2 Job Function is Future
7 16 Work Select/Job 3 Job Function is Future
1
2
0 17 Stop
1 18 Reset
2 19 Reverse
3 20 Start
4 21 Bypass
5 22 Disable Self-check
6 23
7 24
3
0 25
1 26
2 27
3 28
4 29 In 12 Terminal Input 12 not assigned
5 30 In 13 Terminal Input 13 not assigned
6 31 In 14 Terminal Input 14 not assigned
7 32 In 15 Terminal Input 15 not assigned
`