Manual

FEC FUSION Operations Manual Chapter 4: System Setup and Wiring (Rev. 2.1)
Page 4-25
4.8.5 Rear Panel RS232 Alternate Communication Protocol
An alternate communication protocol is available upon set-up in a different “Fastening Func-
tion Mode” (See 7.2.5 Fastening Function Version [Work]-00, [D-No]-03) If the system is set-
up in a “DDK” mode, this protocol becomes the Standard Communication Protocol.
This alternate protocol has 79 bytes of data per fastening.
Byte
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Desc.
Cycle Count
Spindle
Number
Work
Number
ASCII
Hex
30H 30H
30H
31H
20H
20H
30H
31H
20H
20H
20H
31H
20H
20H
Data
0 0 0 1 0 1 1
Byte
15 16 17 18 19 20 21 22 23 24 25 26 27 28
Desc.
Peak Torque Judge
Final Angle Judge
ASCII
Hex
31H 32H
2EH
33H
34H
4CH
20H
20H
20H
20H
35H
30H
48H
20H
Data
1 2 . 3 4 L 5 0 H
Byte
29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
Desc.
Final Torque Judge
1st Rate Judge
ASCII
Hex
31H 32H
2EH
33H
34H
20H
20H
20H
30H
2EH
31H
32H
33H
20H
20H
20H
Data
1 2 . 3 4 0 . 1 2 3
Byte
45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Desc.
2nd Rate Judge
3rd Rate Judge
ASCII
Hex
30H 2EH
31H
32H
33H
20H
20H
20H
30H
2EH
31H
32H
33H
20H
20H
20H
Data
0 . 1 2 3 0 . 1 2 3
Byte
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79
Desc.
1st Time Judge
2nd Time Judge
Final
Judge
CR
LF
ASCII
Hex
20H 31H
30H
2EH
30H
20H
20H
20H
20H
20H
32H
2EH
30H
20H
20H
20H
58H 0DH
0AH
Data
1 0 . 0 2 . 0 X
Final Judgment: “X” Reject = 58H, “O” Accept = 4FH, “A” Abnormal = 41H, “S” Stop=53H, “B” Bypass=42H
Judge: “H” High Reject= 48H, “L” Low Reject= 4CH (H = Hex)