Manual
Chapter 7: System Operations
Page 7-8
7.2.4 Parameter Display Mode
The FUSION system can store up to 16 different sets of parameters that can be selected for fastening
operations via the [
] and [
] keys (Horizontal arrows) or by PLC input signals WORK SELECT 0 ~
3 (see section 4.7.2.) In addition to parameter 1 ~ 16 there is a PARAMETER 0 that contains confi-
guration data common to all parameters.
Parameter display mode displays the preset values programmed in the CONTROLLER unit for fas-
tening operation. When parameter display mode is enabled, the [COUNT/D-NO] display will show 2
digits (00-73) representing the preset data number. The [DATA] display will show the corresponding
preset data value and the parameter display will indicate the parameter number (from 0 ~ 16). Use
the [↓
↓↓
↓] and [↑
↑↑
↑] keys to change the preset data number [D-NO]. If the [COUNT/D-NO] display is show-
ing the number 74 of the parameter number 1, pressing the [↑
↑↑
↑] key will change the [COUNT/D-NO]
display to the number 00 of the parameter number 2.
You can verify the fastening parameters by pressing the [↓
↓↓
↓] and [↑
↑↑
↑] keys at any time. However, it is
not possible to alter these settings in the Run state.
Note: Representation only, not actual data
FIG. 7-2-4a Parameter number selection
Parameter
No.16
Parameter
No.15
Parameter
No.14
Parameter
No.03
Parameter
No.02
Parameter
No.01
00: Fastening Mode
10: Calibration tor-
que
11: Peak Low Tor-
que
12: Peak High To
r-
Parameter
No.00
System Para-
meter
00: Torque Unit
01: NR Version
02: Amplifier Version
03:
Function Version