enFORCE Operation Manual
6.4.5.2 Work Parameters: Parameter Number 01 to 32
Load Settings Distance Settings
Rate Settings Time Settings
Speed Settings Special Settings
¾ Data Number
00 Operation ModeOperation MethodOperation Step
Operation Finish Mode
This data field will set the operation method, operation step and operation finish mode.
Operation Method
0: Load Control
1: Distance Control
2: Load Control Specified Point Load Judgment /
Load Rise Detection
3: Load Control – Time Controlled Press
4: Load Control – Load Drop Detection (Delta f falling)
5: Load Control – Specified Range Peak Load Judgment
6: Load Control – Load Drop Detection (Point Stop)
7: Distance Control With Load Limit
Operation Step
0: 1 Step Operation SNUG Distance Count
1: 1 Step Operation
3: 1 Step Operation 1ST H/L Check
Operation Finish Mode
0: Return
1: [ACCEPT] Return, [REJECT] No Return
2: [ACCEPT] No Return, [REJECT] Return
3: Jog Return
4: Keep Load
5: Load Ignore Return
8: [ACCEPT] and [REJECT] No Return
*For further detailed operation mode instruction, see the following items.
Chapter 6: System Operation