User guide

PAGE 6-11
enFORCE Operation Manual
6.3.5 Press Result Display Mode
The following is displayed on the screen in the Press Result Display Mode.
The [D-NO] changes by pressing the [] and [] buttons.
D-NO DATA UNIT
_0 Peak Load ValueJudgment Load Value KN
_1 Final Distance Value mm
_2 ST Load Rate Value KN/mm
_3 ND Load Rate Value KN/mm
_4 ST Field Operating Time Sec
_5 Final Field Operating Time Sec
_6 Cycle Time Sec
_7 Operating Mode Number
-0 Operating Method Number
-1 Step
-2 Monitornot used
-3 Self Check ON: performed OFF: not performed
-4 Inversion Plug ON: inverted OFF: not inverted
-5
Cause of press stop
0: ResetNo DataAfter hand operated,
1: Abnormal 2: BYPASS signal 3: STOP signal
4: REJECT 5: ACCEPTnormal
-6 Load Judgment Ld H/L
-7 Distance Judgment dS H/L
-8 Load Rate Judgment rt H / L(1
ST
, 1
ST
ZONE) H / L(2
ND
)
-9 Time Judgment Γ H/L(1
ST
H/L(FNL
=0 1
ST
Load Rate Area Increment Load KN
=1 2
ND
Load Rate Area Increment Load KN
=2 1
ST
Final Load KN
=3 1
ST
Peak Load KN
=4 Final Load Value KN
=5 Distance at Peak Load (judge load mm
D-NO DATA
Peak load value
Final Distance value
1ST Load Rate
Distance at Peak Load
Cha
p
ter 6: S
y
stem O
p
eration
D-NOleft side figure
[] / []