User guide
PAGE 6-11
enFORCE Operation Manual
6.3.5 Press Result Display Mode
The following is displayed on the screen in the Press Result Display Mode.
The [D-NO] changes by pressing the [↑] and [↓] buttons.
D-NO DATA UNIT
_0 Peak Load Value(Judgment Load Value) KN
_1 Final Distance Value mm
_2 1ST Load Rate Value KN/mm
_3 2ND Load Rate Value KN/mm
_4 1ST Field Operating Time Sec
_5 Final Field Operating Time Sec
_6 Cycle Time Sec
_7 Operating Mode Number
-0 Operating Method Number
-1 Step
-2 (Monitor)not used
-3 Self Check ON: performed OFF: not performed
-4 Inversion Plug ON: inverted OFF: not inverted
-5
Cause of press stop
0: Reset/No Data/After hand operated,
1: Abnormal 2: BYPASS signal 3: STOP signal
4: REJECT 5: ACCEPT(normal)
-6 Load Judgment Ld H/L
-7 Distance Judgment dS H/L
-8 Load Rate Judgment rt H / L(1
ST
, 1
ST
ZONE) H / L(2
ND
)
-9 Time Judgment Γi H/L(1
ST
) H/L(FNL)
=0 1
ST
Load Rate Area Increment Load KN
=1 2
ND
Load Rate Area Increment Load KN
=2 1
ST
Final Load KN
=3 1
ST
Peak Load KN
=4 Final Load Value KN
=5 Distance at Peak Load (judge load) mm
「D-NO」 「DATA」
Peak load value
Final Distance value
1ST Load Rate
Distance at Peak Load
Cha
p
ter 6: S
y
stem O
p
eration
D-NO:left side figure
0
1
2
5
[↑] / [↓]
buttons