User guide

PAGE 6-4
enFORCE Operation Manual
6.1.2 RS-232C Output Data
Result data is output every time the operation is finished.
The result output is possible for each unit that has a SAN –DP2S/SP4S installed.
Use SAN –IF unit if you want to output multiple results.
Result Output Data
Data Length: 78 bytes fixed (78 letters
Normal data format
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
COUNT Number Press
Number
PARM
Number
30H 30H 30H 31H 20H 20H 20H 20H 30H 31H 20H 20H 20H 31H 20H 20H
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
PEAK LOAD Judg
ment
FINAL DISTANCE Judg
ment
31H 32H 2EH 33H 34H 20H 20H 20H 31H 32H 2EH 33H 34H 20H 20H 20H
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
FINAL LOAD 1ST RATE Judg
ment
31H 32H 2EH 33H 34H 20H 20H 20H 30H 2EH 31H 32H 33H 20H 20H 20H
49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64
2ND RATE Judg
ment
1ST TIME Judg
ment
30H 2EH 31H 32H 33H 20H 20H 20H 20H 31H 30H 2EH 30H 20H 20H 20H
65 66 67 68 69 70 71 72 73 74 75 76 77 78
2ND TIME Judg
ment
Judg
ment
CR LF
20H 20H 32H 2EH 30H 20H 20H 20H 4FH 20H 20H 20H 0DH 0AH
Overall Judgment
"":4FH ACCEPT
"":58H REJECT
"0001 01 1 12.34 12.34 12.34 0.123 0.123 10.0 2.0 O" +CR+LF
Judgment letters displayed beside PEAK LOAD value
H: Exceeded High Value L: Below Low Value
A: Abnormal
S: STOP B: BYPASS (Press Unit Off)
Judgment letter displayed beside DISTANCE, RATE and TIME value
H: Exceeded high value L: Below low value
COUNT Number: ‘0001’ is displayed after powering ON. 1 is added after each cycle.
Cha
p
ter 6: S
y
stem O
p