User guide

PAGE 4-13
enFORCE Operation Manual
WORK SELECT 0 thru 4: Parameter Select signal (Normally Open)
These 5 inputs [WORK SELECT 1-4] form a binary code which is capable of selecting
up to 32 different sets of press parameters.
WORK
SELECT 4
WORK
SELECT 3
WORK
SELECT 2
WORK
SELECT 1
WORK
SELECT 0
Param
No.
MANUAL mode
OFF (OPEN) OFF (OPEN) OFF (OPEN) OFF (OPEN) OFF (OPEN)
Home-position search
OFF (OPEN) OFF (OPEN) OFF (OPEN) OFF (OPEN) ON
Home-position return
OFF (OPEN) OFF (OPEN) OFF (OPEN) ON OFF (OPEN)
Descent high speed jog
OFF (OPEN) OFF (OPEN) OFF (OPEN) ON ON
Ascent high speed jog
OFF (OPEN) OFF (OPEN) ON OFF (OPEN) OFF (OPEN)
Descent middle speed jog
OFF (OPEN) OFF (OPEN) ON OFF (OPEN) ON
Ascent middle speed jog
OFF (OPEN) OFF (OPEN) ON ON OFF (OPEN)
Descent low speed jog
OFF (OPEN) OFF (OPEN) ON ON ON
Ascent low speed jog
OFF (OPEN) ON OFF (OPEN) OFF (OPEN) OFF (OPEN)
(Home-position search)
OFF (OPEN) ON OFF (OPEN) OFF (OPEN) ON 10
(Home-position return)
OFF (OPEN) ON OFF (OPEN) ON OFF (OPEN) 11
(Descent high speed jog)
OFF (OPEN) ON OFF (OPEN) ON ON 12
(Ascent high speed jog)
OFF (OPEN) ON ON OFF (OPEN) OFF (OPEN) 13
(Descent middle speed jog)
OFF (OPEN) ON ON OFF (OPEN) ON 14
(Ascent middle speed jog)
OFF (OPEN) ON ON ON OFF (OPEN) 15
(Descent low speed jog)
OFF (OPEN) ON ON ON ON 16
(Ascent low speed jog)
ON OFF (OPEN) OFF (OPEN) OFF (OPEN) OFF (OPEN) 17
(Home-position search)
ON OFF (OPEN) OFF (OPEN) OFF (OPEN) ON 18
(Home-position return)
ON OFF (OPEN) OFF (OPEN) ON OFF (OPEN) 19
(Descent high speed jog)
ON OFF (OPEN) OFF (OPEN) ON ON 20
(Ascent high speed jog)
ON OFF (OPEN) ON OFF (OPEN) OFF (OPEN) 21
(Descent high speed jog)
ON OFF (OPEN) ON OFF (OPEN) ON 22
(Ascent middle speed jog)
ON OFF (OPEN) ON ON OFF (OPEN) 23
(Descent low speed jog)
ON OFF (OPEN) ON ON ON 24
(Ascent low speed jog)
ON ON OFF (OPEN) OFF (OPEN) OFF (OPEN) 25
(Home-position search)
ON ON OFF (OPEN) OFF (OPEN) ON 26
(Home-position return)
ON ON OFF (OPEN) ON OFF (OPEN) 27
(Descent high speed jog)
ON ON OFF (OPEN) ON ON 28
(Ascent high speed jog)
ON ON ON OFF (OPEN) OFF (OPEN) 29
(Descent middle speed jog)
ON ON ON OFF (OPEN) ON 30
(Ascent middle speed jog)
ON ON ON ON OFF (OPEN) 31
(Descent low speed jog)
ON ON ON ON ON 32
(Ascent low speed jog)
If the start signal is turned “ON” while in MANUAL mode, the press will perform the function
defined in the MANUAL operation of the selected Parameter Number; “Home-position search”,
“Home-position return”, “Descent jog” (Advance) and “Ascent jog” (Return)”.
The speed of the operation of MANUAL mode is set in the Data Number OE: MANUAL SPEED
system parameter. (See Page 6-23The speed of the “Home-position search”, “Home-position
return”, “High speed jog” is set to this set value.
If a value greater than 10mm/sec. is entered, the system will limit Home Position
Search speed to 10mm/sec.
The speed of the “middle speed jog” is set to 1/10 of this set value or the tool’s minimum speed.
The speed of the “low speed jog” is set to 1/100 of this set value or the tool’s minimum speed.
On a “Home Position Search”, the ascent (return) operation operates first and
when the CCW limit sensor turns OFF, the operation changes to descent
(advance) operation. After the CCW limit sensor turns ON again, the motor will
advance until the resolver location (in pulses) is at 0. This point is set to the
zero point and becomes the home position. (See Section 7.2.3.2)
Chapter 4: System Setup and Wiring