User guide

PAGE 4-10
enFORCE Operation Manual
System Parameter 00, D-No. 08 NEAR ORG/BANK1 signal is normally “BANK 1”.
To enable Output Banks 2 & 3, set Parameter 00-08 to ‘2’. (See Page 6-22)
If using the CYCLE OK signal, BANK 1 output is not available in Bank 1.
The BUSY signal is normally used to operate the brake. When changing Banks, the
meaning of the BUSY signal will change when a bank other than Bank 1 is selected.
(See Section 4.14 for Brake Operation)
BANK1 BANK0
OUT DATA
Signal Name Description
OUT DATA0
BYPASS Output when press is in BYPASS
OUT DATA1
ORG OK Output after home position has been defined.
OUT DATA2
POS STOP Output when the cylinder is stopped in home position.
OUT DATA3
BUSY Output while operating.
OUT DATA4
READY Output when the system is READY to operate.
OUT DATA5
ABNORMAL Output when an Abnormal condition occurs.
OUT DATA6
ACCEPT Output when the system has halted without failure.
OUT DATA7
REJECT Output when the system has halted with failure.
OUT DATA8
ADVANCED Output when the press has reached target load or distance.
OUT DATA9
TIMING Output timing signal. Used when Par. 00, D-No. 0A is set.
OUT DATA10
CYCLE OK
BANK1
Output when the press reaches the distance set in Param.
00, D-No. 0A (1~9) / Output echo of Bank Select 1 Input.
OFF OFF
OUT DATA11
BANK0 Output echo of BANK Select 0 Input.
OUT DATA0
OUT DATA1
OUT DATA2
OUT DATA3
WORK SELECT 4
OUT DATA4
WORK SELECT 3
OUT DATA5
WORK SELECT 2
OUT DATA6
WORK SELECT 1
OUT DATA7
WORK SELECT 0
Output echo of selected Input.
OUT DATA8
OUT DATA9
OUT DATA10
BANK1 Output echo of BANK Select 1 Input.
OFF ON
OUT DATA11
BANK0 Output echo of BANK Select 0 Input.
OUT DATA0
LOAD_LOW Output on a Low Load Reject.
OUT DATA1
LOAD_HIGH Output on a High Load Reject.
OUT DATA2
Rt2_LOW Output on a Low Rate 2 Reject.
OUT DATA3
Rt2_HIGH Output on a High Rate 2 Reject.
OUT DATA4
Rt1_LOW Output on a Low Rate 1 Reject or 1
ST
zone High Abnormal
OUT DATA5
Rt1_HIGH Output on a High Rate 1 Reject or 1
ST
zone Low Abnormal.
OUT DATA6
DIS_LOW Output on a Low Distance Reject
OUT DATA7
DIS_HIGH Output on a High Distance Reject.
OUT DATA8
OUT DATA9
OUT DATA10
BANK1 Output echo of Bank Select 1 Input.
ON OFF
OUT DATA11
BANK0 Output echo of Bank Select 0 Input.
OUT DATA0
OUT DATA1
OUT DATA2
OUT DATA3
OUT DATA4
OUT DATA5
OUT DATA6
OUT DATA7
OUT DATA8
OUT DATA9
OUT DATA10
BANK1 Output echo of Bank Select 1 Input
ON ON
OUT DATA11
BANK0 Output echo of Bank Select 0 Input.
Chapter 4: System Setup and Wiring