User guide

PAGE 4-9
enFORCE Operation Manual
4.7 External-Control Signal Connection
Mating Plug
ManufacturerHonda Tsushin Kougyo (HONDA)
Vertical Housing Part No.: MR-34L
Male Insert Part No.: MR-34M
(See Appendix A for connecting cable part numbers)
4.7.1 PLC I/F(AXIS I/O)Signal
IN: Input Signal OUT: Output Signal NC: Normally Closed NO: Normally Open
Only when the MANUAL signal is ON for inputting in to .
Pin No.
Signal Name IN/OUT Description
1 STOP IN (N.C.) Stops System operation upon loss of signal.
2 RESET IN (N.O.) Resets to the initial condition. (>100 ms pulse)
3 MANUAL IN (N.O.) Manual mode.
4 START IN (N.O.) Starts Press Cycle.
5 BYPASS IN (N.O.) Disables Press operation.
6 SYNC COM Synchronizing signal common.
7 SYNC COM Use only for synchronizing signal common.
8 SYNC IN/OUT Synchronizing signal (5V TTL)
9 NEAR-ORG/BANK1 IN (N.O.) Near Origin sensor input/Bank 1 Select.(Use for special applications)
10 OPTION IN IN (N.O.) Use when inputting option and special specification
11 BANK0 IN (N.O.) Bank 0 Select input
12 SYNC IN/OUT Synchronizing signal (5V TTL)
13 IN COMMON Input signal common. (+12 ~ +24VDC)
14 SELF CHECK OFF IN (N.O.) Disable the self-check function.
15 CW LIMIT IN (N.C .) CW limit sensor input.Advance limit
16 CCW LIMIT IN (N.C.) CCW limit sensor input.Return limit
17 WORK SELECT 0 IN (N.O.)
18 WORK SELECT 1 IN (N.O.)
19 WORK SELECT 2 IN (N.O.)
20 WORK SELECT 3 IN (N.O.)
21 WORK SELECT 4 IN (N.O.)
These 5 inputs form a binary code which is capable of selecting up to
32 different parameters.
(In Manual Mode these inputs become selecting signals for advance,
return, home-position search and home-position return operations.)
22 OUT DATA11
OUT (N.O.)
Echo of Bank 0 Select Signal
23 OUT COMMON Output signal common. (0DV)
24 OUT DATA0
OUT (N.O.)
25 OUT DATA1
OUT (N.O.)
26 OUT DATA2
OUT (N.O.)
27 OUT DATA3
OUT (N.O.)
28 OUT DATA4
OUT (N.O.)
29 OUT DATA5
OUT (N.O.)
30 OUT DATA6
OUT (N.O.)
31 OUT DATA7
OUT (N.O.)
32 OUT DATA8
OUT (N.O.)
33 OUT DATA9
OUT (N.O.)
34 OUT DATA10
OUT (N.O.)
Outputs system condition signals based on which Bank is selected.
Echo of Bank 1 Select Signal
Chapter 4: System Setup and Wiring