User guide
PAGE 2-7
enFORCE Operation Manual
2.3.2 Tool Specifications
Motor: Permanent magnet DC
Force Monitor: Inline Load Cell
Distance Monitor: High Resolution Resolver
Tool Type (Fitting)
Full Scale
Load [KN]
Maximum Speed
[mm/sec]
Minimum Speed
[mm/sec]
DPT-021R1-**F
1.96 416.60 0.40
DPT-021R2A-**F
1.96 500.00 0.40
DPT-051R2A-**F
4.90 333.30 0.30
DPT-101R3-**F
9.81 277.70 0.30
DPT-151R3-**F
14.70 277.70 0.30
DPT-201R3-**F
19.60 166.60 0.20
DPT-301R4H-**F
29.40 320.00 0.70
DPT-501R4H-**F
49.00 200.00 0.50
DPT-701R4H-**F
68.60 133.30 0.30
Tool Type(Bonding)
Full Scale
Load [KN]
Maximum Speed
[mm/sec]
Minimum Speed
[mm/sec]
DPT-051R4H-**P
4.90 80.00 0.16
DPT-101R4H-**P
9.81 80.00 0.16
DPT-151R4H-**P
14.71 133.30 0.30
DPT-201R4H-**P
19.61 80.00 0.16
DPT-301R4H-**P
29.42 57.14 0.12
DPT-501R5B-**P
49.03 58.33 0.17
DPT-102R5B-**P
98.10 29.16 0.09
DPT-152R5B-**P
147.10 22.22 0.06
DPT-202R5B-**P
196.10 16.37 0.05
*Standard part numbers shown. Contact FEC for non-standard part specifications.
1KN = 224.81 Lbs.
Chapter 2: Specifications