User guide

PAGE 6-41
enFORCE Operation Manual
¾ Data Number 17 - Threshold Load
The starting point of calculation of 1
ST
Rate.
This also sets the “Low” value when using 1
st
Step Hi/Low check.
A setting is possible from 0 to 105% of full-scale value.
If
rate supervision is not needed, set Threshold to the Full Scale Load
value. Threshold will not be detected, so rate supervision will not be
performed.
¾ Data Number 18 - Crossover Load
¾ Data Number 24 - Crossover Distance
The starting point of calculation of 2
ND
Rate.
A setting is possible from 0 to 105% of full-scale value.
Crossover Distance can also be used as the end point for Slowdown Speed.
In Load Control methods:
In Distance Control methods:
Chapter 6: System Operation
Load
Distance
Threshold
1ST
RateMinimum
RateMaximum
Load
Distance
CROS
Standard Load
Rate Minimum
Rate Maximum
Load
Distance
CROS
Target
Rate Minimum
Rate Maximum