Owner's manual
enFORCE Operation Manual
PAGE 4 - 9
Chapter 4: System Setup and Wiring
4.7 External-Control Signal Connection
Mating Plug
Manufacturer:Honda Tsushin Kougyo (HONDA)
Vertical Housing Part No.: MR-34L
Male Insert Part No.: MR-34M
(See Appendix A for connecting cable part numbers)
4.7.1 PLC I/F(AXIS I/O)Signal
IN: Input Signal OUT: Output Signal NC: Normally Closed NO: Normally Open
Pin No. Signal Name IN/OUT Description
1 STOP IN ( N.C.) Stops System operation upon loss of signal.
2 RESET IN (N.O.) Resets to the initial condition. (>100 ms pulse)
3 MANUAL IN (N.O.) Manual mode.
4 START IN (N.O.) Starts Press Cycle.
5 BYPASS IN (N.O.) Disables Press operation.
6 NOT USED No Connection Allowed
7 NOT USED No Connection Allowed
8 NOT USED No Connection Allowed
9 HOME / BANK1 IN (N.O.) Home sensor input(Use for special applications)/Bank 1 Select.
10 OPTION IN IN (N.O.) ※Use when inputting option and special specification
11 BANK0 IN (N.O.) Bank 0 Select input
12 NOT USED No Connection Allowed
13 IN COMMON Input signal common. (+12 ~ +24VDC)
14 SELF CHECK OFF IN (N.O.) Disable the self-check function.
15 CW LIMIT IN (N.C.) CW limit sensor input.(Advance limit)
16 CCW LIMIT I N ( N. C.) CCW limit sensor input.(Return limit)
17 WORK SELECT 0 IN (N.O.) These 5 inputs form a binary code which is capable of selecting up to
32 different parameters.
(In Manual Mode these inputs become selecting signals for advance,
return, home-position search and home-position return operations.)
18 WORK SELECT 1 IN (N.O.)
19 WORK SELECT 2 IN (N.O.)
20 WORK SELECT 3 IN (N.O.)
21 WORK SELECT 4 IN (N.O.)
22 OUT DATA11
OUT (N.O.)
Echo of Bank 0 Select Signal
23 OUT COMMON Output signal common. (0VDV)
24 OUT DATA0
OUT (N.O.)
Outputs system condition signals based on which Bank is selected.
Echo of Bank 1 Select Signal
25 OUT DATA1
OUT (N.O.)
26 OUT DATA2
OUT (N.O.)
27 OUT DATA3
OUT (N.O.)
28 OUT DATA4
OUT (N.O.)
29 OUT DATA5
OUT (N.O.)
30 OUT DATA6
OUT (N.O.)
31 OUT DATA7
OUT (N.O.)
32 OUT DATA8
OUT (N.O.)
33 OUT DATA9
OUT (N.O.)
34 OUT DATA10
OUT (N.O.)