Owner's manual

enFORCE SAN Unit Operation Manual
PAGE 6 - 22
Cha
p
ter 6: S
y
stem O
p
eration
¾ Data Number 0B Approach Distance LimitLoad Cell Availability
This data field sets the maximum approach distance and availability of the load cell.
Load Cell Availability
0: With Load Cell (Default) 1: Without Load Cell
Approach Distance Limit (Default = 000)
If you set 200, the approach distance will be up to 200mm.
*Example: If the load transducer is used and the approach distance limit is 200mm, the
setting will be 2000.
¾ Data Number
0C Current Load Conversion Ratio [percentage] (Default = 100)
This data field sets the conversion ratio (as a percentage) of current control without the
load transducer.
A setting of 0~100 is possible.
¾ Data Number
0D Stroke Distance LimitLoad Hold Time Decimal Point
It sets the maximum distance stroke allowed (except for approach distance) and decimal
point of the Load Hold Time.
Load Hold Time Decimal Point
0: X.X (Default) 1: no decimal point
Stroke Distance Limit (Default = 000)
If you set 200, distance settings other than approach distance
will be limited to 200mm.
*Example: If the stroke distance limit is 200mm and there is no decimal point required,
the setting will be 2001.
¾ Data Number
0E Manual Operation Speed (Default = 10~30)
This data field sets the speed of MANUAL operations. The speed of the [home position
search], [home position return] and [high speed jog] is set to this speed.
*The maximum speed of the [home position search] is 10mm/sec.
The speed of the [middle speed jog] is 1/10 of the set value or the slowest speed of
the attached tool.
The speed of the [slow speed jog] is 1/100 of the set value or the slowest speed of the
attached tool.
¾ Data Number
0F Dynamic Hold / RS232 Data Format / Speed Decimal Point
Speed Decimal Point
0: XXXX (no decimal point), 1: XXX.X, 2: XX.XX
Do not change the setting unless it is necessary
because the speed decimal point is fixed for each
tool when shipped.
RS-232C Equipment Data Format Setting
0: Printer 1: Monitor 2: LVDT(digital gauge)
Dynamic Hold
0: Dynamic Hold ON 1: Dynamic Hold OFF
If Dynamic Hold option is set to 1 (OFF), system will
automatically be set to SERVO OFF mode after the
operation has finished.
Special Specification
0: Normal
1: SAN2 Compatible Mode
2: The result data will not be reported for parameter number 32.
(For systems with Return function set on parameter 32)