Owner's manual
enFORCE SAN Unit Operation Manual
PAGE 6 - 21
Cha
p
ter 6: S
y
stem O
p
eration
¾ Data number 08 Home Position Sensor Availability/PLC Bank Select Enable
□ □ □ □
0: No Home Position sensor (Default)
1: Home position sensor attached (on presses 10 ton and larger)
2: Bank Select enable (enable output signal banks 2 & 3)
0: Enable Distance High Limit Stop (Default)
1: Disable Distance High Limit Stop
0: 0.1mm distance sampling (Default)
1: 0.01mm distance sampling
2: 0.005mm distance sampling
Operation of setting bank change
OUT DATA Banks can be selected by PIN number 9: HOME POSITION SENSOR /
BANK 1 or 11: BANK 0 signals of the PLC I/O Connector.
See Section 4.7 “External Control Signal Connection” for further details.
Allow a minimum of 20ms to read the Bank 0 and Bank 1 Echo Outputs
when using the Data Bank Select signals
¾ Data number
09 Home Position Search Time Out [0~999.9sec] (Default = 120.0)
It sets the time limit of the home position search operation.
*If the operation has not finished within the time limit an abnormal will occur.
¾ Data number
0A Distance Decimal / Deadman / Data Speed / Special Setting
□ □ □ □
Distance decimal
0: No decimal, 1: X.X, 2: X.XX 3: X.XXX
*This is factory preset. Do not change unless necessary.
You need to re-input the data if changing the distance
decimal because the decimal point of all the distance-
related data will be changed.
0: Normal Operation (Deadman Mode Disabled)
1: Home Positioning function is in Deadman Mode
2: Automatic Return function is in Deadman Mode
3: Home Positioning
& Automatic Return is in Deadman Mode
0: RS-485 9600bps RS-232C 9600bps
1: 19200bps 9600bps
2: 38400bps 9600bps
3: 9600bps 19200bps
4: 19200bps 19200bps
5: 38400bps 19200bps
6: 9600bps 38400bps
7: 19200bps 38400bps
8: 38400bps 38400bps
*Power must be cycled for these changes to take effect.
0: No output function
1: Sets Pin #34 option output ON 1mm before the target distance
9: Sets Pin #34 option output ON 9mm before the target distance
*Using settings 1-9 also enables the Timing signal (Pin #33).
Distance data is set up in Param. 1-32, D-No. 30, 31, 32 and 33.
30: Advance ON Distance 31: Advance OFF Distance
32: Return ON Distance 33: Return OFF Distance