Owner's manual

enFORCE SAN Unit Operation Manual
PAGE 6 - 10
Cha
p
ter 6: S
y
stem O
p
eration
6.3.4 Real Time Display Mode
The following data is displayed on the screen in the Real Time Display Mode.
The [D-NO] changes by pressing the [] and [] buttons.
D-NO DATA
0
Load value display
Displays present load applied on the load cell in real time.
1
Load voltage value display
Displays present load signal voltage applied on the load cell in real time.
2
Maximum load value display (Maximum value hold)
Displays peak load from the time when the [RESET] switch was last pressed in this mode.
3
Moving distance display
Displays distance of absolute position from the home position.
Press and hold [SET] to see the 3 decimal place resolution value.
4
Electronic thermal value (Overload at 100)
Present electronic thermal value is displayed.
5
Current value (Max 1023)
Displays present current value.
6
Resolver position data display (0 to 4093)
Displays present resolver position.
7
Input and Output signal monitor (Software version 1.96 or later)
Displays ON/OFF state of PLC I/F input and output signal. (See below for details.)
8
For in-house use only
Input and output signal monitor
* This can be used for software version 1.96 or later of the SAN unit.
D-NO: 1 figure
0
1
2
[], []
switch
“D-NO” DATA
Load value display
Load voltage value
display
Maximum load value
display
n
ON: Light on OFF: Light off