User guide
enFORCE DSP1500 Main Unit Hardware Manual
(Rev. 4.0) PAGE 5 - 76
Chapter 5: Control Interfaces
Select the DATA TYPE format (BCD or ASCII).
Data from the Main and SAN Unit (Press) must be configured in the table below each tab. The
MAIN FORMAT contains the “Header” data (such as Date, Time, Sequence #, Cycle Count, etc.
– aka data that comes from the Main Unit) The PRESS FORMAT contains the actual press
pressing data (such as Load, Distance, Parameter, etc.) Right click on the table and select the
item that you wish to be transferred from the pop up window.
(Example of Main format selection shown above)
Note: Selecting “Null” deletes the item from the list.
Main
Format
Data
BCD ASCII
Byte
LSB Data MSB
Byte
LSB Data MSB
Cycle Count 1234567 4 01 23 45 67 7
31
1
32
2
33
3
34
4
35
5
36
6
37
7
Date 2006/12/20 4 20 06 12 20 10
32
2
30
0
30
0
36
6
2F
/
31
1
32
2
2F
/
32
2
30
0
Time 12:34:56 4 12 34 56 00 8
31
1
32
2
3A
:
33
3
34
4
3A
:
35
5
36
6
Total
Judgment
REJECT
2
01 00
3
52
R
45
E
4A
J
ACCEPT 02 00
41
A
43
C
43
C
ABNORMAL 04 00
41
A
42
B
4E
N
STOP 08 00
53
S
54
T
50
P
BYPASS 10 00
42
B
59
Y
50
P
START OFF 20 00
53
S
54
T
4F
O
ABN.- STOP 40 00
41
A
42
B
53
S
BYP.- STOP 80 00
42
B
59
Y
53
S
Sequence
No.
1 2 01 00
2
30
0
31