User guide
4.8.4 Allen Bradley Input Card 1771-IQ16 Axis Unit Connection
FIG. 4-8-4 Allen Bradley Input Card 1771-IQ16 Axis Unit Connection
Note: The 0 VDC Common is connected directly to the Axis Unit PLC connector on Pin 7. The
+12~24 VDC Common is connected directly to Pin 6, and is shown on the PLC Output Card
sheet (FIG. 4-8-2) for the Axis Unit.
Chapter 4: System Setup and Wiring
Page 4-34