User guide


Common for all of the analog outputs.ANALOG GROUND 16
Analog Torque Output (Analog output -4.5 ~ +4.5 VDC)
A 0 ~ 2.5 VDC differential signal. Example: Zero = -2.0 VDC
Calibration (full scale) = +0.5 VDC Difference = 2.5 VDC
ANALOG TORQUE
OUTPUT
15
Angle Pulse Output (Analog output 0~5 VDC)
Outputs one pulse per degree.
ANGLE PULSE
OUTPUT
14
DESCRIPTIONSIGNAL NAMEPin #
4.7.5 Axis Unit Bank Select Table
Output when Fastening resulted in a Final
Time Reject.
FINAL TIME
OVER REJECT
BANK DATA 3
Output when Fastening resulted in a 1st
Time Reject.
1ST TIME OVER
REJECT
BANK DATA 2
Output when Fastening resulted in a 3rd
Torque Rate Low Reject.
3RD RATE LOW
REJECT
BANK DATA 1
Output when Fastening resulted in a 3rd
Torque Rate High Reject.
3RD RATE HIGH
REJECT
BANK DATA 0ONON4
Output when Fastening resulted in a 2nd
Torque Rate Low Reject.
2ND RATE LOW
REJECT
BANK DATA 3
Output when Fastening resulted in a 2nd
Torque Rate High Reject.
2ND RATE HIGH
REJECT
BANK DATA 2
Output when Fastening resulted in a 1st
Torque Rate Low Reject.
1ST RATE LOW
REJECT
BANK DATA 1
Output when Fastening resulted in a 1st
Torque Rate High Reject.
1ST RATE HIGH
REJECT
BANK DATA 0OFFON3
Output when Fastening resulted in an
Angle Low Reject.
ANGLE LOW
REJECT
BANK DATA 3
Output when Fastening resulted in an
Angle High Reject.
ANGLE HIGH
REJECT
BANK DATA 2
Output when Fastening resulted in a
Torque Low Reject.
TORQUE LOW
REJECT
BANK DATA 1
Output when Fastening resulted in a
Torque High Reject.
TORQUE HIGH
REJECT
BANK DATA 0ONOFF2
Individual spindle BYPASS output.BYPASSBANK DATA 3
Individual spindle ABNORMAL output.ABNORMALBANK DATA 2
Individual spindle ACCEPT output.ACCEPTBANK DATA 1
Individual spindle REJECT output.REJECTBANK DATA 0OFFOFF1
DESCRIPTIONNAME OF
SIGNAL
BANK DATA
PINS 1, 10, 9, 8
0
PIN 3
1
PIN 2
BANK
#
AXIS UNIT BANK DATA
BANK
SELECT
INPUT
Chapter 4: System Setup and Wiring