Manual
2.1 System Specifications
wPower Supply Voltage
P 200 to 230 VAC ±10%, 3-phase, 50/60 Hz
wInstallation Requirement
P NEMA 12 enclosure
wRange of Operation
P Duty cycle within 50% (reference Section 2.2: Duty Cycle Calculation.)
P Additional specifications will be provided for nutrunners greater than 50 kgm.
wOperating Conditions (may be met by incorporating an air-handling unit into system)
P Temperature: 0° - 50°C (32° to 122°F)
P Humidity: 20% to 90%, no moisture
wStorage Conditions
P Temperature: -5° to 55°C (23° to 131°F)
P Humidity: Below 90%, no moisture
wShipping Conditions
P Temperature: -5° to 55°C (23° to 131°F)
P Humidity: Below 90%, no moisture
P Each item (component or assembly) must be sealed in bubble wrap.
P All metal parts (except for the electric motor, encoder and connectors) must be
greased or oiled to prevent rust.
Chapter 2: Specifications
Page 2-2