Manual


DSUB 9-pin female communication connector. (Option)RS42225
(NOT USED)24
(NOT USED)23
DSUB 15-pin female VGA CRT (monitor) connector. May be
used to connect an optional LCD Display.
CRT22
DSUB 9-pin male input connector.RS232C CH221
MINI DIN 6-pin keyboard/keypad connector.K / B20
Backup battery for System clock.(INSIDE - NOT VISIBLE)19
(NOT USED)18
200~230 VAC, 50/60 Hz, single phase input power
connector.
AC-POWER AC200~230V17
DSUB 9-pin male output connector.RS232C CH116
DSUB 25-pin female Centronics parallel printer connection.PRINTER15
Interface connector for System input/output control lines.
(Refer to Chapter 4 for details)
PLC214
Interface connector for System input/output control lines.
(Refer to Chapter 4 for details)
PLC113
Hard disk drive, IDE interface.(INSIDE - NOT VISIBLE)12
Manual pushbutton for Calibration (Cal) Check.(MANUAL) CAL11
Manual pushbutton to reverse tool rotation.(MANUAL) REV10
Manual pushbutton for fastening start.(MANUAL) START9
Manual pushbutton for System reset and Zero Check.(MANUAL) RESET8
Operation mode selector (key) switch. RUN mode allows
equipment to operate, and PROGRAM is the data entry
(presetting) mode.
RUN / PROGRAM7
Rotary switch for selecting which items are to be displayed
on the Axis Unit at DSP1 and DSP2. (Refer to the Axis Unit
Display Table in Section 3.2.4)
AXIS-DSP6
Display LED (orange) that indicates when either a Cal Check
or a Zero Check is being performed.
CHECK 5
Display LED (orange) that indicates when the fastening cycle
is in process.
BUSY 4
Display light (red) that indicates when an unacceptable
fastening, Zero Check, or Cal Check is complete.
REJECT3
Display light (green) that indicates when an acceptable
fastening, Zero Check, or Cal Check is complete.
ACCEPT2
Floppy disk drive: 3.5" 1.44MB Notebook computer style.FDD1
DESCRIPTION (REFERENCE FIGURE 3-2-3)ITEM AS MARKED ON UNIT
AFC1200 ISA MAIN CONTROLLER UNIT - CONTROLS AND INDICATORS
Chapter 3: System Description
Page 3-7