User guide
3RD TORQUE RATE LOW Low limit for 3rd TORQUE RATE
7.1.10 VOCABULARY LIST 4 [SPEED]
FIG. 7-1-10 set parameter [SPEED]
OFFSET CHECK SPEED Nutrunner speed during OFFSET CHECk
1ST TIME 1st STEP time limit in multi-step fastening
FINAL TIME 1st Step to end of fastening time limit in multi-step fastening
INITIAL TIME [SEC] -- Time (in seconds) to run at initial speed
[REV] -- Number of revolutions at initial speed
INITIAL SPEED nUTRunner speed during initial start
FREERUN TIME [SEC] -- Time (in seconds) for high speed rundown
[REV] -- Number of revolutions for high speed rundown
FREERUN SPEED NUtrunner speed during pre-rundown
SLOW DOWN SPEED NUtrunner speed during seat to 1st Step
TORQUE SPEED Nutrunner speed from 1st Step to end of fastening
Note: Set eITHer seconds [SEC] or revolutions [REV] for freerun and initial time, but not both.
Chapter 7: System Operation
Page 7-23