User guide


CONSTANT Compensation factor for permanent elongation
(default = 1.00)
NOTE: CROSsover points can be set in either torque or angle, but not both.
CROSSOVER AREA Threshold 2 Torque plus area angle = Area Yield Method
ANGLE calculation start point
CROSSOVER AREA Area Yield Method calculation start point
TORQUE
1ST TORQUE Seat torque (1st TORQUe), end of 1st TORQUE RAte
measurement, start of 2nd TORQUE RAte measurement
1ST ANGLE SEat angle (1st Angle), end of 1st TORQUE RATE
measurement, start of 2nd TORQUE RATE measurement
CROSSOVER RATE 2 End of 2nd TORQUE RATe measurement, start of
3rd
ANGLE TORQUE RAte measurement, start of INTEGRATED Yield
Method calculation
CROSSOVER RATE2 end of 2nd TORQUE RATe measurement, start of 3rd
TORQUE TORQUE RATe measurement, start of INTEGRATED Yield
Method calculation
SPEED CHANGE shiftpoint from 1st STep to torque speed
TORQUE
THRESHOLD 1 TORQUE sTart of 1st TORQUE RATE measurement
THRESHOLD 2 TORQUE Start of FINAL Angle measurement
2ND ANGLE ANgle for 2nd Step in multi-step fastening
3RD ANGLE ANgle for 3rd Step in multi-step fastening
2ND TORQUE TOrque for 2nd Step in multi-step fastening
3RD TORQUE torque for 3rd Step in multi-step fastening
HIGH TORQUE High torque limit
LOW TORQUE LOw torque limit
HIGH ANGLE High final angle limit
LOW ANGLE LOw final angle limit
1ST TORQUE RATE HIGH HIgh limit for 1st TORQUE RATE
1ST TORQUE RATE LOW LOw limit for 1st TORQUE RATE
2ND TORQUE RATE HIGH HIgh limit for 2nd TORQUE RATE
2ND TORQUE RATE LOW Low limit for 2nd TORQUE RATE
3RD TORQUE RATE HIGH High limit for 3rd TORQUE RATE
Chapter 7: System Operation
Page 7-22