User guide


(standard operating method)
YIELD METHOD
(CW/CCW) Yield Control method
SPEED CHANGE TORQUE Shiftpoint from 1st Step to torque speed
THRESHOLD 1 TORQUE Start of 1st TORQUE RAte measurement
THRESHOLD 2 TORQUE STart of FINAL ANGLE measurement
1ST TORQUE SEat torque (1st Torque), end of 1st TORQUE RAte
measurement, start of 2nd TORQUE Rate measurement
CROSSOVER RATE 2 END of 2nd TORQUE Rate measurement, start of 3rd torque
TORQUE Rate measurement
2ND TORQUE TORque for 2nd Step in multi-step fastening
3RD TORQUE TORque for 3rd Step in multi-step fastening
STD TORQUE FINal target torque in TORQUE Control mode, end of 3rd
TORQUE RAte measurement
HIGH TORQUE HIgh torque limit
LOW TORQUE LOw torque limit
HIGH ANGLE HIGh final angle limit
LOW ANGLE LOw final angle limit
INCREMENT ANGLE Preset angle for INTEGRATED TORQUE Rate
1ST TORQUE RATE HIGH High limit for 1st TORQUE RAte
1ST TORQUE RATE LOW low limit for 1st TORQUE RATe
2ND TORQUE RATE HIGH HIGh limit for 2nd TORQUE Rate
2ND TORQUE RATE LOW LOw limit for 2nd TORQUE RATE
3RD TORQUE RATE HIGH HIgh limit for 3rd TORQUE Rate
3RD TORQUE RATE LOW Low limit for 3rd TORQUE RAte
Chapter 7: System Operation
Page 7-18