User guide


2-3b. The pulldown menu will display three input mode selections:
[FASTENING] Fastening parameter set screen
[SPEED] Speed parameter set screen
[REVERSE] Reverse parameter set screen
2-3c. Using the
[↑] [↓]
keys, select the desired input mode and depress the
[↵]
key. The selected input mode screen will now be displayed.
FIG. 7-1-2-3 set parameter [INPUT MODE]
7.1.3 Fastening Parameter Setup
The function of this screen is to preset the following parameters:
Fastening method Yield (control values)
Tool type Yield (monitor values)
Torque (control values) Torque rate (monitor values)
Torque (monitor values) Angle (control values)
Angle (monitor values)
3-1. Select Fastening Method
3-1a. Move the cursor on the menu bar to [INPUT MODE], select [FASTENING] and
depress the
[↵]
key. The screen displayed will be the "SET PARAMETER
(FASTENING)" screen. (Check the PARAMETER No. to ensure the correct number
has been selected).
3-1b. Depress the [SEL] key. The fastening method will be highlighted. Use the
[←]
[→]
keys to scroll through the fastening method options and depress the
[↵]
key to
select an option. The screen will change to the "SET PARAMETER (FASTENING)"
screen for the selected fastening method.
NOTE: Clockwise (CW) or counterclockwise (CCW) fastening is chosen as part of the fastening
method.
For Angle Method, three (3) options are available: CCW, CW SNUG and CW SEAT.
Typically, SNUG method should be chosen for a clockwise fastening. (SEAT method is
primarily used in Systems operating outside of the United States.)
FIG. 7-1-3-1 set parameter Fastening method selection
Chapter 7: System Operation
Page 7-10