Chapter 4: Individual Part Names. Chapter 3: System Description 3.
Chapter 3: System Description (Rev. 8/98) FIG.
Chapter 3: System Description (Rev. 8/98) 3.1.1 System Block Diagram Description { The System construction provides programming and data collection control for up to 32 spindles through the use of a single optional User Console or Printer Interface Unit (PIFU). { Communication for up to 32 Axis Units (Spindle Controllers) is accomplished via an RS422 Daisy chain connection on the front of each Axis unit.
Chapter 3: System Description 3.2 3.2.1 (Rev. 8/98) Component Description AFC1100 Front panel, switches and connectors 1 2 3 4 START REV CAL RESET DATA D-NO ANGL 6 5 PARM SPNO ABN 7 DATA MODE SET ABN BUSY 8 REJECT ACCEPT TORQUE ANGLE LOW (ORANGE) 1ST RATE HIGH BYPASS (RED) 2ND RATE 1st (ORANGE) TIME FNL (RED) 9 10 RS422 IN RUN 11 15 BYPASS OUT ENCODER MOTOR 12 13 16 T/D TQ./ ANG. OUT 17 14 AC-IN AXIS I/O 200V 230V AFC-1100 SYSTEM AXIS CONTROLLER FIG.
Chapter 3: System Description Item as called out on Figure 3.2.1 (Rev. 8/98) Description 1 (MANUAL) START Manual fastening start pushbutton. 2 (MANUAL) REV Manual reverse pushbutton. 3 (MANUAL) CAL Manual Calibration (Cal) Check pushbutton. 4 (MANUAL) RESET Manual Zero Check and System reset pushbutton. 5 MODE Display mode selection pushbutton. Refer to Chapter 7. 6 SET Data change confirmation pushbutton. 7 ↑ - Up Data change increase pushbutton.
Chapter 3: System Description (Rev. 8/98) 3.2.2 AFC1100 Front panel display description 1 2 3 4 7 8 9 13 14 15 5 START REV CAL RESET DATA D-NO 6 ANGL PARM SPNO ABN 10 MODE BUSY DATA SET ABN REJECT ACCEPT TORQUE ANGLE LOW (ORANGE) 1ST RATE HIGH BYPASS 11 12 (RED) 2ND RATE TIME 1st (ORANGE) FNL (RED) RS422 IN RUN BYPASS OUT ENCODER MOTOR T/D TQ./ ANG. OUT AC-IN AXIS I/O 200V 230V AFC-1100 SYSTEM AXIS CONTROLLER FIG.
Chapter 3: System Description ITEM AS MARKED ON UNIT (Rev. 8/98) DESCRIPTION (REFERENCE FIGURE 3-2-2) 1 D-NO Display number that indicates what the data in the "DATA" and "ANG/SPNO" display represents. 2 PARM/ABN Displays one-digit Parameter number and, as needed, will override Parameter output to display an Abnormal code. Refer to Chapter 9 for Abnormal display code descriptions.
Chapter 3: System Description (Rev. 8/98) 3.2.3 Nutrunner (Tool) Unit FIG. 3-2-3 Nutrunner (Tool) unit { ENCODER P Environmentally isolated angle encoder. P Provides feedback for speed regulation to Servo Amplifier. P Provides angle monitoring capability to fastening operation. { MOTOR P Totally enclosed DC permanent magnet motor. P Refer to Chapter 2 for various motor sizes. { TRANSMISSION P Planetary gear transmission. P Available in straight and offset models. P Refer to Section 2.5.
Chapter 3: System Description (Rev. 8/98) 3.2.4 PRBU-DFT Unit (Preamplifier Cable Extender) P This unit can extend the preamplifier cable of the DFT tool up to 100 feet. P The maximum length of the preamplifier cable without this unit is 50 feet. P An external power supply is not required for this unit. P Figure 3-2-4 below illustrates the unit dimensions (in millimeters), and the recommended positioning of the unit within the system. MAX. 50 FEET MAX.