Data Sheet

FeasyBeacon FSC-BP104 Datasheet
4 www.feasycom.com
6. Configurable Parameters
Parameters in the below table are configurable by FeasyBeacon SDK compiled app (e.g.
FeasyBeacon app), feel free to download FeasyBeacon app from Google Play App Store
or iOS App Store.
Parameter
Description
Device Name
UTF-8 string, Default: FSC-BP104-XXXXXX
Pin Code
Access password to FSC-BP104
Default: 000000, Range: 000000 ~ 999999
Advertising Interval
Default: 1300 ms, Range: 100 ~ 10000 ms
Tx Power
Maximum Tx power: +2.5 dBm
Default: 0 dBm, Range: -19.5 ~ +2.5 dBm
Eddystone-URL
URL
URL that needed to be advertising
RSSI at 0m
A 1-byte value representing the average received signal strength at
0m from the advertiser (FSC-BP104), range: 0 ~ -127
Eddystone-UID
Namespace
10-byte Namespace
Instance
6-byte Instance
Reserved
Reserved for future use
RSSI at 0m
A 1-byte value representing the average received signal strength at
0m from the advertiser (FSC-BP104), range: 0 ~ -127
iBeacon
UUID
16-byte UUID, e.g. FDA50693A4E24FB1AFCFC6EB07647825
Major
2-byte Major, range: 0 ~ 65535
Minor
2-byte Minor, range: 0 ~ 65535
RSSI at 1m
A 1-byte value representing the average received signal strength at
1m from the advertiser (FSC-BP104), range: 0 ~ -127
AltBeacon
ID1
Beacon Identifier 1
ID2
Beacon Identifier 2
ID3
Beacon Identifier 3
RSSI at 1m
A 1-byte value representing the average received signal strength at
1m from the advertiser (FSC-BP104), range: 0 ~ -127
Manufacturer ID
The beacon device manufacturer's company identifier code
Manufacturer
Reserved
Reserved for use by the manufacturer to implement special features