Datasheet
Cell Type CR-1/3N
Typical Characteristics
Specifications
Nominal capacity is determined to an end voltage of 2.0V when the battery is
allowed to discharge at a standard current level at 23
o
C.
*1
Current value is determined to be the level at which 50% of the nominal
capacity is obtained with an end voltage of 2.0V at 23
o
C.
*2
Current value for obtaining 2.0V cell voltage when pulse is applied for
15seconds at 50% discharge depth at 23
o
C.
*3
Discharge Characteristics of CR1/3N
Cell Voltage(V)
Duration(hour)
Cell Voltage(V)
Duration(minute)
Discharge Characteristics of CR1/3N
Discharge Characteristics of CR1/3N
Cell Voltage(V)
Duration(hour)
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
1.0
1.5
2.0
2.5
3.0
3.5
60
o
C
23
o
C
0
o
C
Load:41ohm(= 57mA)
0 10 20 30 40 50 60 70 80
1.0
1.5
2.0
2.5
3.0
3.5
60
o
C
23
o
C
0
o
C
-20
o
C
-40
o
C
Load:1kohm(=2.7mA)
0 10 20 30 40 50 60 70 80
1.0
1.5
2.0
2.5
3.0
3.5
Load: 1kohm(= 2.7mA)
Temp.:23
Initial
after 100days storage at 60
C
o
C
o
Capacity(mAh)
Discharge Load(kohm)
Discharge Load vs. Capacity of CR1/3N
0.1 0.5 1 5 10 50
0
50
100
150
200
250
end voltage:2.0V
60
o
C
23
o
C
0
o
C
-20
o
C
These are just measured data. Not guaranteed.
3
160
2
60
80
-20 ~ +60
3.3
D 11.6
H 10.8
d 7.8
Dimensions (mm)
Nominal Voltage (V)
Nominal Capacity (mAh)
*1
Standard Discharge Current (mA)
Weight (g)
Max. Discharge Current (mA)
Temperature Range (
o
C)
Continuous
*2
Pulse
*3
04. 2014
H
D
d