SDS
SECTION 5 - FIRE-FIGHTING MEASURES
Flash Point: Lower Explosive Limit: Upper Explosive Limit:
Extinguishing Techniques:
Equipment:
Chemical Hazards from Fire:
Precautions for Fire Fighters:
SECTION 6 - ACCIDENTAL RELEASE MEASURES
Steps to be Taken:
Cleanup Procedures:
SECTION 7 - HANDLING AND STORAGE
Precautions to be Take
in Handling & Storage:
Incompatibility:
SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION
INGREDIENTS: EXPOSURE LIMITS
Eye Protection: Protective Gloves: Respiratory Protection:
Ventilation Requirements Local Exaust: Mechanical:
Room Ventilation is Adequate:
SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES
Appearance & Odor: Flammable Limits: Upper: Lower:
Boiling Point (
0
F): Specific Gravity (H20) (+0.005): pH (+ 0.5)
Vapor Pressure (mm Hg) Vapor Density (Air=1)
Solubility in Water: Complete Insoluble Emulsifiable (or Dispersible) Slightly (or Partial)
Evaporation Rate (vs H2O) Faster Slower About the Same
Flash Point (T.C.C.):
0
F Odor Threshold:
Melting point/frozen point:
Partition Coefficient: n-octanol/water:
Auto-Ignition Temperature:
Decomposition Temperature:
Viscosity:
SECTION 10 - STABILITY AND REACTIVITY
Stability: Incompatibility:
Hazardous Decomposition Products:
None to boiling
Not available
Not available
Fog, nozzle, water
Do not enter any confined fire-spaces without protective clothing and self-contained air supply.
Strong oxidizer. May ignite combustible or organic materials when in contact. chlorine gas may be present in fire.
Cool fire exposed containers.
SMALL AMOUNTS - Absorb with non organic absorbent. LARGE AMOUNTS - Absorb with non organic
absorbent, then shovel into appropriately labeled containers.
Contain with absorbent material and dispose of in accordance with federal, state and local
requirements.
Store in a cool, well-ventilated place away from acids and ammonia. Do not mix with
any other chemical. Do not get in eyes, skin or clothing. Store in a well ventilated
place. Avoid breathing mists or vapors. Keep container closed.
organic compounds, ammonia, amines, acids
Sodium Hydroxide 1310-73-2
2 mg/m3(ceiling)(OSHA); 2mg/m3(ceiling)(ACGIH)
Chlorine 77-82-50-5
1 ppm(OSHA); 1 ppm TWA(ACGIH)
✔
✔
✔
✔
Amber liquid, characteristic odor
Not available
Not available
Appx. 212
1.083
13.0
Not available
Not available
✔
none to boiling
Not available
✔
Not available
Not available
Not available
Not available
Not available
Stable
Organic compounds,ammonia, amines, acids
Carbon monoxide and unidentified organic gases may occur during incomplete combustion.