Oil & Gas Wireless Enabled Monitoring System 43
Installer’s Guide
iWPM-T-Specific Menus
The iWPM-T tabs include menus for calibrating the pressure and temperature
sensors on the iWPM-T device. Figure 3-25 below shows the menu for calibrating
the pressure sensor, and Figure 3-26 on the following page shows the temperature
sensor calibration menu. Luna iMonitoring calibrates all of the iWPM-T’s sensors
before shipping.
iWPM-T Pressure Sensor Calibration
To set the pressure calibration parameters, select the Pres Cal tab at the bottom
of the screen to access the pressure calibration menu shown in Figure 3-25 below.
Select the proper Units from the pull-down list. The choices for Units are millivolts,
PSI, mm Hg, kPa, and mBar. Enter the correct Slope and Intercept for the specified
units, and hit the Set Pressure Cal button.
Figure 3-25.
i
WPM-T Pressure Sensor Calibration Menu.