Operation Manual

9.13. Connection for RS232 Interface
The FMD55 has also an RS232 interface, on which a serial external
printer or a p.c. system can be connected for printing out or
processing stored data respectively. (See also Ch. 4.5.)
Decode or stored data can be transported to a PC for further
processing. The output happens analogue to the internal printer
print out. Should the print out of the internal printer not function
simultaneously then connect pins 5 and 8 together
The following programmes are suited for data processing:
xWindows Terminal programme
xNorton Commander
xX-Talk for Microstuff
The Baud rate at the interface is 9600 Bd. This means that any
printer with a serial interface with 9600 Bd and FX80 emulation can
be connected. Character length 8 bit, zero parity bit, one stop bit.
Plug assignment - see the next diagram.
9.14 Connection for NMEA Interface
When the FMD55 is to be used as a navigation log or an NMEA
printer, an NMEA unit e.g. GPS, must be connected. The
connections TX+/- of the NMEA ex ternal unit must be connected
with the RX+/- of the FMD55. The TX+/- of the F MD55 are not active
and are only for factory tests.