Operation Manual
All the system parameters will now be printed out in an orderly
list.
The NAVTEX parameters must be printed out separately in the
NAVTEX menu (see Ch. 5.8.)
Storing of data:
All stored data, such as system parameters, receiver
parameters, timer status, stored messages etc. remain stored
for at least 3 months, and under optimal conditions up to 12
months. This is possible because of the integrated NiCd
battery, which is continually charged when the unit is in
operation.
It is recommended that in a case, where the unit should be
out of operation for a longer period, that you print out the
system data and the NAVTEX parameters and file them.
Should their be a loss of data, you can re-enter the old data
from the print out.
8.5. Deletion of Memory Store and RESET
All programmed system parameter data can be deleted i.e.
can be reset to the standard parameters. Equally, all stored
messages can be deleted. In this case the programmed timer
status, navigation log status and NAVTEX parameters will also
be deleted. It is therefore recommended, that you
print out
the system and NAVTEX status, before you commence this
function (see chapters 8.4. and 5.8.)
To activate the deletion function:
1. switch off the unit by turning <OFF>
2. press and hold key <CLEAR> and
3. switch unit back on
4. release the <CLEAR> key briefly and
5. repress <CLEAR>
www.Busse-Yachtshop.de email: info@busse-yachtshop.de