Operation Manual

5.8. Printing Out of NAVTEX Parameter Status
For control purposes all selected parameters can be printed
out. This print out will show the frequency, filter, selected
messages and stations as well as a list of stored NAVTEX
messages.
xFrom the <NAVTEX> mode press No. <7>
xTo return to <NAVTEX> mode press <EXIT>
5.9. Returning to Basic Standby Mode
This can be done by pressing the <EXIT> key
three
times or
the keys <8>, <8> and <3> in this sequence.
5.10. Displaying and Dealing with Errors
The SITOR code used by NAVTEX can recognise errors. Every
data field, to which a character has been assigned, will be
repeated and have a relationship of 4:3 bit. Only when both
data fields match and are valid does the corresponding
character appear as a capital letter. Should it be
recognised as valid only once, then it will appear as a small
letter. If both assigned data field characters be non-valid,
then it will appear as an * (asterisk). It is not common form of
expression. We are of the opinion that a small letter holds
more information than an asterisk *.
5.11 Termination of High Error Rate
When deciphering NAVTEX, the error rate of the decoded
signal will be examined. Should the acceptance rate be
exceeded, then the print out, if activated, will be
interrupted and the message will be automatically deleted
from the memory store.
www.Busse-Yachtshop.de email: info@busse-yachtshop.de