Owner manual

FasTest, Inc. 1646 Terrace Drive Roseville, MN 55113 Support: (800) 444-2373 Fax: (651) 645-7390 www.fastestinc.com
8
Bail Handle Compressed Gas Connectors
MAINTENANCE
Maintenance Checklist
Daily
Inspect for Leak-tight seal
The main seal must be replaced more frequently depending on wear. Dismantling of the
connector for this purpose is not required. It is recommended that an O-ring pick be used for
removal to avoid damage to the groove
Clean groove if required and insert new O-ring
Inspect for correct function.
Does the safety pin properly protrude and lock the connector under pressure?
Does the safety pin move backwards when the system is depressurized?
Weekly
Inspect for correct function
Inspect the correct engagement of the collets
Check the connector’s collet thread with gauge
Check for any bent or missing components
Periodic
Inspect that all threaded components are tight and properly torqued
Check for any bent or missing components
Check for proper actuation of handle, collets and all moving components
Check for leaks