Dimensions Guide
ESR-1078 
|
 Most Widely Accepted and Trusted  Page 8 of 8 
TABLE 5—CONNECTION GEOMETRY REQUIREMENTS
1
CONDITION 
MINIMUM DISTANCE OR SPACING (inches) 
TimberLOK, OlyLog 
and HeadLOK 
LedgerLOK, 
LogHog, TrussLOK 
and TrussLOK-Z 
ThruLOK 
End distance 
Loading toward end 
3 
3
3
/
4
3
3
/
8
Loading away from end 
2 
2
3
/
8
2
3
/
8
Loading perpendicular to grain 
2 
2
3
/
8
2
3
/
8
Edge distance 
Any load direction 
1
3
/
4
1
3
/
4
2 
Spacing between fasteners in a row 
Loading parallel to grain 
2
7
/
8
3
1
/
2
3
1
/
2
Loading perpendicular to grain 
2 
2
3
/
8
2
3
/
8
Spacing between rows 
In-line rows 
1 
1
1
/
4
1
1
/
4
Staggered rows
2
1
/
2
5
/
8
5
/
8
For SI: 1 inch = 25.4 mm. 
1
End distances, edge distances and screw spacing must be sufficient to prevent splitting of the wood, or as required by this table, whichever is more 
restrictive. 
2
Values for spacing between staggered rows apply where screws in adjacent rows are offset by half of the spacing between screws in a row. 
TABLE 6—RECOGNIZED EXPOSURE CONDITIONS FOR COATED FASTENMASTER LOK SERIES FASTENERS
1
EXPOSURE 
CONDITION 
TYPICAL APPLICATIONS 
RECOGNITION LIMITATIONS 
1 
Treated wood in dry use applications 
Limited to use where equilibrium moisture content of the chemically treated 
wood meets the dry service conditions as described in the NDS. 
3 
General construction 
Limited to freshwater and chemically treated wood exposure, e.g., no 
saltwater exposure. 
1
Recognized exposure conditions apply only to FastenMaster LOK Series fasteners having the recognized proprietary corrosion-resistant coating with a 
lubricious clear top coat. 
TABLE 7—PRODUCT NAME CORRELATION 
OMG PRODUCT NAME 
CORRESPONDING NAME FOR MITEK INDUSTRIES 
TimberLOK/OlyLog 
- 
HeadLOK 
- 
LedgerLOK 
- 
LogHog 
- 
TrussLOK 
TrussLOK-EWP 
TrussLOK-Z 
TrussLOK-Girder 
ThruLOK 
- 