Figure 70 - License Key Entry Page
Figure 71 - A reboot is required to apply the Licence Key
5.4.11 Administration - Timing
This page allows the Timing parameters to be configured (SyncE only on Single-port versions, and both SyncE
and IEEE1588v2 on Dual-port versions). Note that setting of these parameters should only be performed by a
trained installer, as incorrect configuration may result in the link being dropped.
SyncE mode may be configured as either:
None: This is the default setting, SyncE is disabled. This is the recommended setting unless a Primary
Reference Clock input is available.
Provider: Use this setting if a Primary Reference Clock or other Synchronous Ethernet timing signal is
available on the Ethernet port. Note that only one end of the link may be configured as SyncE “Provider”,
and the remote end must be configured as “Consumer” in this case.