Figure 60 - Installation – Normal Mode
Note: In order to prevent false transitions into alignment mode due to the alignment cap not being correctly
fitted and producing a false open-circuit, it is possible to use the GUI button “change mode” to force the unit from
Alignment mode into Normal mode: in this case, the System Mode will display “Normal (Locked)” and removal of
the alignment cap will not change back to Alignment mode, and there will not be any voltmeter reading
available. The only way to unlock the mode to allow Alignment mode again, is to press the “Change Mode” button
on the GUI again.
Figure 61 - Home page showing System Mode in Alignment mode
The Installation page also allows the Link Identifier to be set. The Link Identifier should be the same on both
ends of the link, or else the link will not be established. In the case of a mismatch in Link Identifier, a warning
message will be displayed.