Figure 14 Rolling Sphere Method for Determining Lightning Protection Zone
3.6 Cabling
The terminal is delivered with an Ethernet cable terminated with a RJ-45 connector. To connect the
Liberator-V1000 radio terminal to your network, use a Cat 5e Ethernet cable with a maximum length of 100
metres to the next network node. The recommended cable specifications are:
CAT5e Cable
Outdoor Industrial Rated (includes rating for UV protection)
Solid or Multi-Braided Screen (avoid cables with a metalised plastic foil screen)
Screened RJ45 Connectors
Since the power is supplied by the Ethernet cable, please make sure that network equipment used supports
power over Ethernet to the “Ultra PoE” or “PoE
++
” specification.
3.7 Co-located Applications
Owing to the compact size of the Liberator-V1000 integrated terminal, it may be used for co-sited
applications (see the section titled Co-located Terminals).