Figure 14 – Rolling Sphere Method for Determining Lightning Protection Zone
3.6 Cabling
The terminal is delivered with an Ethernet cable terminated with a RJ-45 connector. To connect the
Liberator-V1000 radio terminal to your network, use a Cat 5e Ethernet cable with a maximum length of 100
metres to the next network node. The recommended cable specifications are:
•
CAT5e Cable
•
Outdoor Industrial Rated (includes rating for UV protection)
•
Solid or Multi-Braided Screen (avoid cables with a metalised plastic foil screen)
•
Screened RJ45 Connectors
Since the power is supplied by the Ethernet cable, please make sure that network equipment used supports
power over Ethernet to the “Ultra PoE” or “PoE
++
” specification.
3.7 Co-located Applications
Owing to the compact size of the Liberator-V1000 integrated terminal, it may be used for co-sited
applications (see the section titled Co-located Terminals).