Installation Guide
IBR Installation Guide
Page 23 of 32 Doc # 770-00001-3
Aug. 30, 2013
(3) Use screws to secure the two plates together as shown below. Screws #4 should be
torqued to a maximum of 5 ft-lbs (69 kgf-cm). (NOTE: IBR is shown inverted from the
way it should be mounted.)
(4) Materials provided with this mount are shown in the table below.
ITEM #
QTY
PART #
DESCRIPTION
1
1
430-00014
Bracket, IBR Pole/Wall Mount, Wall Plate
2
1
430-00016
Bracket, IBR Pole/Wall Mount, IBR Plate
3
4
470-00007
Screw, M8x1.25mm, SS, Button Head
4
2
470-00008
Screw, M6x10, SS, SHCS
5
4
495-00001
Washer, M8, SS, Split Lock
6
2
495-00002
Washer, M6, SS, Split Lock