Manual
Troubleshooting HA450 / HA650 V. 1.0
27
5 Troubleshooting
5.1 Contact service
1. Find the type plate on the rear of the machine. See § 3.1.5.
2. Take a note of the model number and the serial number of the
machine.
3. Contact your supplier or manufacturer.
See www.fast-fluid.com
.
5.2 Sound signals
Note
For all error messages on the computer: see the help topic in the dispense
software.
Sound signal Possible cause Solution
xxxxxx
S-O-S signal during stirring.
The agitation motor is
malfunctioning, cable broken or
board malfunctioning.
Contact your supplier.
xxxxxx
S-O-S signal rotation turning table.
The brush motor is malfunctioning. Contact your supplier.
- - - - >
1 sec. on, 1 sec off... etc....
Stirring function cannot start
because the upper cover (#1).
Close cover and/or door.
xxxxx
5 x short
‘Valve timeout‘ Restart machine.
xx
2 x short
Beeper test when starting up /
initializing.
-
!
long uninterrupted beep
Brush container door open during
dispense.
Close the brush container door.
!
long uninterrupted beep
Switch plate activated during
dosage.
Check Switch plate, move can
table downwards.
x
1 x short
The upper cover is open when the
machine starts to dispense, or
when the can table moves.
Close upper cover.