Manual

26
Troubleshooting GA450 V. 2.2
5.3 Troubleshooting guide
5.3.1 Easy-to-solve errors
5.3.2 Clamp plate errors
5.3.3 Inverter errors
Problem Possible cause Possible solution
The display shows ‘E00’ Emergency stop is pressed during
idle state.
Release the emergency stop. See § 5.4.
The display shows ‘E01’ The door is open. Close the door.
The display shows ‘E05’ The cradle lock failed to release
the cradle.
Reset the machine. See § 5.4.
When the problem persists, contact
service. See § 5.2.
The display shows ‘E08’ Emergency stop is pressed during
running state.
Release the emergency stop. See § 5.4.
The display shows ‘E11’ No can found during clamping or
can is too small.
Install a can. See § 3.2.4.
Problem Possible cause Possible solution
The display shows ‘E40’ Home sensor not found. Reset the machine. See § 5.4.
When the problem persists, contact
service. See § 5.2.
The display shows ‘E41’ Top of clamp plates is not reached
in time.
Reset the machine. See § 5.4.
When the problem persists, contact
service. See § 5.2.
The display shows ‘E42’ Clamp plate is sticking on can.
Cradle lock is stuck.
Reset the machine. See § 5.4.
When the problem persists, contact
service. See § 5.2.
The display shows ‘E43’ Clamp plate is stuck in up position.
Cradle lock is stuck.
Reset the machine. See § 5.4.
When the problem persists, contact
service. See § 5.2.
Problem Possible cause Possible solution
The display shows ‘E50’ Inverter is in error mode. Reset the machine. See § 5.4.
When the problem persists, contact
service. See § 5.2.
The display shows ‘E51’ Failed to initialize inverter. Reset the machine. See § 5.4.
When the problem persists, contact
service. See § 5.2.
The display shows ‘E54’ Failed to run the mixer motor
forward.
Reset the machine. See § 5.4.
When the problem persists, contact
service. See § 5.2.