Maintenance
A - Daily maintenance
Clean the nozzle closure, refill canisters and run morning program
>
>
Replace the pad. Refill the
cup with water or cleaning
fluid until the pad is soaked.
Fill canisters if level is low
and update levels in software.
Stir colorant beforehand.
Start software morning
program to purge valves and
clean nozzles. Check your
software manual for details.
Use only cleaning fluids recommended by your paint supplier. Wrong
materials can result in nozzle blockage and reduced accuracy.
B - Weekly maintenance
Remove spilt paint & colorant and refill canisters
>
>
Clean can table and outside
parts with diluted detergent.
Clean outside parts with
diluted detergent.
Check canister content and
refill if necessary.