Instruction Manual
C.  Route wire harness along frame to the approximate mounting location near the fuel tank. Completion 
of this step will be addressed in the Step 3. 
B.  Secure  Relay  in  an  upright position,  as  shown, to  prevent  moisture  from  entering. Di-electric  grease 
may be applied to prevent corrosion.  Examples of locations to secure relay: 
A.  Using  ring terminals,  attach  red  wire  of  the  WH-1004  to  the  positive 
battery  terminal.  Attach  green  wire  to  a  clean  ground,  preferably  the 
negative  battery terminal.  Secure  fuse  block in  a location protected 
from outside  elements.  The  use  of  corrosion  preventative  spray  is 
recommended. 
The installation of the electrical harness is done first, allowing power to be applied to the pump for 
lubrication purposes later in the installation.  
Note: The FASS harness provided has a 15 amp fuse and the 30 amp fuse provided 
loose in the kit is to be installed on the wiring harness due to the volume and torque 
the FASS pump is producing.  