User guide
E.  Slid the FASS pump into mounting brackets with the weep hole facing down.  Torque (4) bolts to 110 
inch pounds. 
VERY IMPORTANT:  REMEMBERING THE  POSITION OF THE “T”  PORT,  THERE IS  A  SMALL WEEP HOLE  IN 
THE  BASE  DIRECTLY  NEXT  TO  THE  ELECTRIC  MOTOR,  THIS  HOLE  MUST  AIM  DIRECTLY  TO  THE 
GROUND!!  IMPROPER  INSTALLATION  OF  THE  PUMP  CAN  CAUSE  PREMATURE  WEAR  AND  VOID  MANU-
FACTURES WARRANTY.  
D.  Using thread tape, install the 2 10-300 into the “T” & “E” ports. Torque to 40 ft./lbs. Connect the male 
end of the wire harness to the female electrical connector on the FASS pump. Reconnect the battery. 
Turn key to the “On” position.  With the FASS pump on, squirt a liberal  amount of WD-40 or other 
lubricant into the “T” port. This procedure will “wet” the Gerotor and allow for better suction during 
initial priming. Note: Do Not Put Thread Tape on Flare of Fitting  