4.0 Installation Verification
The following information applies to an installation with an access panel. Refer to the
Troubleshooting the Reader Installation section beginning on page 21 if the reader is not
functioning properly.
4.1 Grounding
Shield (Drain) continuity must run from the reader to the access panel. Shield (Drain) and
reader ground must be tied together at the access panel and connect to an earth ground
in one place.
4.2 Power
A reader may be powered by the access panel, so the reader is powered on when the
access panel is powered on. However the best case is to power the readers by a separate
linear power supply. When powered, verify the voltage at the reader meets the reader's
requirements (refer to Table 1 on page 3). When the reader is powered on, its beeper
beeps in the following pattern: 3 short beeps, 1 long beep.
4.3 Controls
Beeper (the blue wire): Pull the beeper line low to activate the beeper.
•Single LED
1
Control Line Mode (the brown wire)
- The normal state is for this line to be high activating the Red LED.
- Pull the Single LED line low to activate the Green LED.
- Toggle the Single LED line to activate the Amber LED.
Dual LED
1
Control Line Mode
2
(the brown and orange wires)
- The normal state is to pull both LED lines high (brown and orange) to turn the LED
Off.
- Pull both lines low (brown and orange) to activate the Amber LED.
- Pull the Brown wire high and pull the Orange wire low to activate the Green LED.
- Pull the Brown wire low and the Orange wire high to activate the Red LED.
1. The P-400 Reader does not have an LED to maximize its vandal resistance.
2. Only Single LED Control Line mode is active when the reader is in Magnetic Stripe mode. The
Dual LED Line is not used.