3.4 P-600 Rocky Reader and Keypad Mounting Instruc-
tions
When mounting to a flat surface, three holes need to be drilled to mount the P-600's
electronics package (refer to Figure 4:). One large hole (1 inch - 25.5 mm) accommodates
the beeper and the reader cable (please note that the beeper and reader cable hole is not
located on the reader's center line). Two small pilot holes for a #6 screw (1/8 inch - 3 mm)
are for mounting the electronics package on a wall surface.
Drilling is not required if the reader is to be mounted to a standard U.S. single gang
electrical box - the electronics package is mounted directly to the electrical box.
Figure 4: : P-600 Mounting Diagram