A reader may be powered by the access panel, so the reader is powered on when the access supply is powered on.
However the best case is to power the reader by a separate, linear power supply.
7.0 Voltage
• Can range from 5 to 14 VDC, 12 VDC is nominal
8.0 Reader Wiring
Please note that at minimum the power, ground, data 0, and data 1 lines must be connected to the access panel.
Other lines are for additional functionality.
9.0 Connections in Detail
Wire Color Line I/O Description
Red Reader Input voltage Input 5 to 14 VDC
Green Wiegand data 0/
Magstripe Clock
Output Wiegand data or ABA Track II clock
White Wiegand data 1/
Magstripe Data
Output Wiegand data or ABA Track II data
Brown Red LED host control Input LED host control. In single line LED control
mode (default mode) pull line low to turn on
green LED. In dual line LED mode pull line
low to turn on Red LED
Orange Green LED host
control
Input LED host control, only used in dual LED mode.
In dual LED mode pull line low to turn on
green LED.
Blue Audio tone host
control
Input Beeper host control. Pull line low for beep.
Purple Read mode control Input Read mode host control. Pull line low for
“CSN Only” mode.
Yellow Card Present Output (can be
configured as TTL or
open collector)
Card present line for ABA Track II magnetic
stripe output.
Black Reader Ground Input Reader Ground
Silver Cable shield N/A Cable shield (drain), should be grounded
Wire
Color
Function
Green
Blue
Red
Pur
p
le
Brown
Shield
(
Drain
)
White
Yellow
Black
Silver
Data
0
Bee
p
er
Reader
Power
Read
Mode
LED
line
1
LED
line
2
Data
1
Card
Present
Reader
Ground
Oran
g
e
Figure 1: Wiring Connections to Access Panel
Access
Panel
Reference Document Delta Series Mifare Readers