SHR 200
Heat Recovery Ventilator
Product #: 99225
Fantech's side port connection HRV for budget conscious house projects,
the SHR 200 unit brings a continuous supply of fresh air into a home
while exhausting an equal amount of contaminated air. During winter,
fresh incoming air is tempered by the heat that is transferred from the
outgoing air so you save on energy costs, while during summer, the
incoming air is pre-cooled if the house is equipped with an air cooling
system. The SHR 200 is equipped with automatic defrost mechanisms
so you can use your HRV all year long.
Features
Fans with backward curved blade
Electrostatic filters (washable)
Aluminum heat recovery core
Removable screw terminal for easy connection
Lighweight 59.5 lbs (27Kg)
Multiple speed operation
Optional Controls
ECO-Touch™
(#44929) Programmable Touch Screen Wall Control
EDF7
(#44883) Electronic multi-function dehumidistat
EDF1
(#40375) Multi-function dehumidistat
RTS2
(#40164) 20 minute timer over-ride
RTS5
(#44794) 20/40/60 minute timer
MDEH1
(#40172) Dehumidistat
Specifications
Duct size 6" (152 mm)
Voltage/Phase 120/1
Power rated 240 W
Amp 2.3 A
Average airflow 195 cfm (92 L/s)
@ 0.4" P
s
(100Pa)
Fans
Two (2) factory-balanced fans with backward curved blades. Motors come
with permanently lubricated, sealed ball-bearings to guarantee long life
and maintenance-free operation.
Heat Recovery Core
Aluminum heat recovery core covered by a limited lifetime warranty. Core
dimensions are 12” x 12” (305 x 305 mm) with a 15” (380 mm) depth.
Our heat exchangers are designed and manufactured to withstand
extreme temperature variations.
Defrost
A preset defrost sequence is activated at an outdoor air temperature of
23°F (-5°C) and lower. During the defrost sequence, the supply blower
shuts down & the exhaust blower switches into high speed to maximize
the effectiveness of the defrost strategy. The unit then returns to normal
operation, and continues cycle.
Serviceability
Core, filters, fans and drain pan can be easily accessed through latched
door. Core conveniently slides out on our new easy glide core guides. 22"
(559 mm) of clearance is recommended for removal of core.
Case
24 gauge galvanized steel. Baked powder coated paint.
Insulation
Cabinet is fully insulated with 1” (25 mm) high density expanded
polystyrene.
Filters
Two (2) washable electrostatic panel type air filters 11.75” (298mm) x
15” (380mm) x 0.125” (3mm).
Controls
External three (3) position (Low/Stand By/Medium) rocker switch that will
offer continuous ventilation. Fantech offers a variety of external controls.
(see controls)
Installation
Unit is typically hung by using installation kit supplied with unit. Mounting
bolts provided on top four (4) corners of unit. An optional wall bracket is
available.
Warranty
Limited lifetime on aluminum core, 7 year on motors, and 5 year on
parts.