Specification
PERFO RMANCE C URVES
Fantech provides you with independently
tested performance specifications.
The performance curves shown in this brochure are
representative of the actual test results recorded at
Texas Engineering Experiment Station/Energy Systems
Lab, a recognized testing authority for HVI. Testing was
done in accordance with AMCA Standard 210-85 and
HVI 916 Test Procedures. Performance graphs show air
flow vs. static pressure.
Use of HP Series fans in low resistance applications such as bathroom venting will result in
elevated sound levels. We suggest FR Series or other Fantech fans for such applications.
HP Series Fans are Specially
Designed with Higher
Pressure Capabilities for
Radon Mitigation Applications
MOST RADON MITIGATORS WHO PREVIOUSLY USED THE FANTECH
FR SERIES FANS HAVE SWITCHED TO THE NEW HP SERIES.
Fan
Model
HP2133
HP2190
HP175
HP190
HP220
Wattage
Range
14 - 20
60 - 85
44 - 65
60 - 85
85 - 152
Max.
Amps
CFM vs. Static Pressure in Inches W.G.
0.17
0.78
0.57
0.78
1.30
Max.
Ps
0.84
1.93
1.66
2.01
2.46
0"
134
163
151
157
344
0.5"
68
126
112
123
260
0.75"
19
104
91
106
226
1.0"
-
81
70
89
193
1.25"
-
58
40
67
166
1.5"
-
35
12
45
137
1.75"
-
15
-
18
102
2.0"
-
-
-
1
58
Volts
115
115
115
115
115
HP2133 – For applications where lower pressure and flow are needed.
Record low power consumption of 14-20 watts! Often used where there is
good sub slab communication and lower Radon levels.
HP2190 – Performance like the HP190 but in a smaller housing.
Performance suitable for the majority of installations.
Fans are attached to PVC pipe using flexible couplings.
For 4” PVC pipe use Indiana Seals #156-44, Pipeconx PCX 56-44 or equivalent.
For 3” PVC pipe use Indiana Seals #156-43, Pipeconx PCX 56-43 or equivalent.
4 1/2"
1 1/4"
1 1/4"
6 5/8" 9 3/8"
2.00
1.80
1.60
1.40
1.20
1.00
0.80
0.60
0.40
0.20
0.00
0 20 40 60 80
Flow Rate (CFM)
Static Pressure (In. H2O)
120100 140 160 180
HP2133
HP2190
NOTE:
Installations that will result in condensate forming in the outlet ducting should have a condensate
bypass installed to route the condensate outside of the fan housing. Conditions that are likely to
produce condensate include but are not limited to: outdoor installations in cold climates, long lengths
of outlet ducting, high moisture content in soil and thin wall or aluminum outlet ducting. Failure to
install a proper condensate bypass may void any warranty claims.
HP FEATURES INCLUDE
• Improved UV resistant housings
approved for commercial
applications.
• UL Approved for Wet
Locations (Outdoors)
• Sealed housings and wiring boxes
to prevent Radon leakage or water penetration
• Energy efficient permanent split capacitor motors
• External wiring box
• Full Five Year Factory Warranty
PERFO RMANCE DATA
HP2133 & HP2190 RADON MITIGATION FANS
Tested with 4" ID duct and standard couplings.